Filter Assemblies & Housings

Order and customize your order quickly and easily.

FSL High Viscosity Filtration Systems

A dedicated contamination solution for bulk oil handling and fluid transfer. Designed to excel in filtering particulate from heavily contaminated oil, the FSL keeps gearbox lubricant clean and equipment running efficiently.

Ideal for high viscosity gearbox or lube applications and highly contaminated fuel applications.

FSL SPECIFICATIONS

Dimensional
Height
50” (127 cm)
Width
22” (56 cm)
Depth
28” (71 cm)
Weight
222 lbs (101 kg)
Connections
Inlet with 3-way valve
FSL05-FSL10: 1” FNPT FSL20-FSL30: 1.5” FNPT
Outlet
FSL05-FSL10: 1” FNPT FSL20-FSL30: 1.25” FNPT
Operating Temperature
Fluid Temperature
30°F to 225°F (0°C to 105°C)
Ambient Temperature
-4°F to 104°F (-20C to 40C)
Materials of Construction
Vessel
Carbon steel with industrial coating
Electric Motor
TEFC, 56-215 frame
0.5-3 hp, 1450-1750 RPM, see Appendix for amp ratings.
Motor Starter
MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.
Pump
Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Pump Bypass
Full bypass at 150 psi (10 bar)2
Pneumatic Option Air Consumption
~40 cfm @ 80 psi3
Operating Temperature
M
Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000
A
Microglass high performance media combined with water removal scrim. βx[C] ≥ 4000
W
Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2)
Viscosity
2-5000 cSt4
Fluid Compatibility
Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options.
Hazardous Environment Options
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord or cord reel will be included.

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. Dimensions are approximations taken from base model and will vary according to options chosen.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 800 cSt for sizing requirements.

Filter Assemblies & Housings

Order and customize your order quickly and easily.
vacuum dehydrator

V1P model shown,V1S model shown

V1 Compact VUD Vacuum Dehydrator

A compact and mobile dehydration and high efficiency filtration solution, the V1 prevent acidity and loss of lubrication properties caused by inefficient dehydration and high ingression.

Ideal for rapidly removing all forms of water including free, emulsified, and dissolved water and gas from hydraulic and lube oils.

FSL SPECIFICATIONS

Model
V1P
V1S
Height 1
50” (127 cm)
50” (127 cm)
Width 1
28” (71 cm)
34” (86 cm)
Depth 1
28” (71 cm)
24” (61 cm)
Weight 1
400 lbs (181 kg)
400 lbs (181 kg)
Inlet
¾” male JIC
¾” male JIC
Outlet
½” male JIC
½” male JIC
Operating Temperature
Fluid Temperature
32°F to 180°F (0°C to 82°C)
Ambient Temperature
-4°F to 104°F (-20C to 40C)
Materials of Construction
Frame
Carbon steel or stainless steel
Filter assembly
Aluminum and carbon steel
Electric Motor
TEFC with overload protection
Electric Connection
50’ (15 m) power cord supplied with machine.
Pump
Cast iron, positive displacement gear pump with internal relief.
Vacuum Pump
Dry Rotary Vane
Media Description
M
Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000
W
Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2)
Fluid Compatibility
Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester or skydrol fluid compatibility select fluid compatibility from special options.

1. Dimensions are approximations taken from base model and will vary according to options chosen.

Filter Assemblies & Housings

Order and customize your order quickly and easily.
cart

Filter Assemblies & Housings

A fully self-contained mobile solution for bulk oil handling, fluid transfer and reservoir or gearbox conditioning.

Ideal for lower viscosity hydraulic oil, lube oil and diesel fuel.

FSL SPECIFICATIONS

Dimensional
Height
45” (114 cm)
Width
20” (50 cm)
Depth
23” (58 cm)
Weight
125 lbs (57 kg)
Connections
Inlet
FC05-FC5: 1” male JIC (37° flare) FC10: 1.25” male JIC (37° flare)
Outlet
FC05-FC10 1” male JIC (37° flare) FC20: 1.25” male JIC (37° flare)
Hoses
FC05-FC5: 1” x 10 ft (2.4 m) FC10:1.25” x 10 ft (2.4 m) suction
1” x 10 ft (2.4 m) discharge
Operating Temperature
Fluid Temperature
30°F to 225°F (0°C to 105°C)
Ambient Temperature
-4°F to 104°F (-20C to 40C)
ΔP Indicator Trigger
22 psi (1.5 bar). Consult factory for other options.
Filter Assembly Bypass
25 psid (1.7 bard). Consult factory for other options.
Materials of Construction
Frame
Industrial coated steel
Filter Assembly
Aluminum head & canister
Hoses
Reinforced synthetic
Wands
Stainless Steel
Electric Motor
TEFC, 56-215 frame

0.5-3 hp, 1450-1750 RPM
Electric Connection
Voltages 230 V ac and under, single phase: 35’ (11 m) retractable cord reel included. NEMA 5-15 plug installed on Power Option 12. Voltages over 230 V ac: 35’ (11 m) power cord included.
Motor Starter
MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.
Pump
Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Pump Bypass
Full bypass at 150 psi (10 bar)2
Pneumatic Option Air Consumption
~40 cfm @ 80 p~40 cfm @ 80 psi3

35’ (11 m) retractable air hose included when pneumatic option selected (replaces electric cord reel).si3
Operating Temperature
M
Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000
A
Microglass high performance media combined with water removal scrim. βx[C] ≥ 4000
W
Stainless steel wire mesh media βx[C] ≥ 2
Viscosity
2-5000 cSt4
Fluid Compatibility
Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options.
Hazardous Environment Options
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord will be included.

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. 10 GPM pump is rated for intermittent duty only at pressures above 100 psi. Continual operation with dual clogged filters resulting in operating pressures over 100 psi will reduce pump life and/or cause premature pump failure.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 200 cSt for sizing requirements.

Filter Assemblies & Housings

Order and customize your order quickly and easily.
Filter Assemblies & Housings

Filter Assemblies & Housings

Remove water and particulate to extend fuel injector life and increase combustion engine fuel efficiency. Ideal for large mining and construction fueling depots, diesel fueled turbines, backup generators, and smaller day tank dispensing or on-board fueling truck applications. With options for adding nonpowered units to existing fuel dispensing lines, there’s a perfect COD for all of your diesel applications.

FSL SPECIFICATIONS

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. Female pipe port.
3. L38-CSV element combines coalesce and separator element functions into a single element. TEFLON® is a registered trademark of DuPont.

Filter Assemblies & Housings

Order and customize your order quickly and easily.
Filter Assemblies & Housings

Filter Assemblies & Housings

A dedicated contamination solution for bulk oil handling, fluid transfer and reservoir or gearbox conditioning.

Enhance cleanliness by adding the FPL to an existing hydraulic system and extend the life of in-line filters.

FSL SPECIFICATIONS

Dimensional
Height
22” (58 cm)
Lenght
42” (107 cm)
Depth
12” (31 cm)
Weight
138 lbs (63 kg)
Connections
Inlet with 3-way valve
1” FNPT
Outlet
1” FNPT
Operating Temperature
Fluid Temperature
30°F to 225°F (0°C to 105°C)
Ambient Temperature
-4°F to 104°F (-20C to 40C)
ΔP Indicator Trigger
Standard MF110 Assemblies
18 psi (1.2 bar)
Special Options D1 + S1 (S75/D)
22 psi (1.5 bar)
Special Option D2 (DFN)
32 psid (2.2 bard)
Special Option P1 (PFH)
73 psid (5 bard)
ΔP Indicator Trigger
Standard MF110 Assemblies
25 psid (1.7 bard)
Special Options D1 + S1 (S75/D)
25 psid (1.7 bard)
Special Option D2 (DFN)
50 psid (3.4 bard)
Special Option P1 (PFH)
102 psid (7 bard)
Materials of Construction
Frame
Carbon steel with industrial coating
Electric Motor
TEFC, 56-145 frame
0.5-1 hp, 1450-1750 RPM
Motor Starter
MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.
Pump
Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Pump Bypass
Full bypass at 150 psi (10 bar)2
Pneumatic Option Air Consumption
~40 cfm @ 80 psi3
Media Description
M
Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000 (βx ≥ 200)
A
Microglass high performance media combined with water removal scrim. βx[C] ≥ 4000 (βx ≥ 200)
W
Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2)
Viscosity
2-5000 cSt4
Fluid Compatibility
Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or
Hazardous Environment Options
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord will be included.

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. 10 GPM pump is rated for intermittent duty only at pressures above 100 psi. Continual operation with dual clogged filters resulting in operating pressures over 100 psi will reduce pump life and/or cause premature pump failure.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 800 cSt for sizing requirements.

Filter Assemblies & Housings

Order and customize your order quickly and easily.
Filter Assemblies & Housings

Filter Assemblies & Housings

A self contained solution for high viscosity bulk oil handling, fluid transfer and reservoir or gearbox conditioning.

Ideal for higher viscosity lube oil and highly contaminated fuel and hydraulic oil.

FSL SPECIFICATIONS

Dimensional
Height
57” (144 cm)
Width
30” (77 cm)
Depth
30” (77 cm)
Weight
351 lbs (159 kg)
Connections
Inlet with 3-way valve
FCL05-FCL5: 1” male JIC (37° flare) FCL10: 1.25” male JIC (37° flare)
Outlet
FCL05-FCL10: 1” male JIC (37° flare) FCL20-FCL30: 1.25” male JIC (37° flare)
Hoses
FCL05-FCL5: 1” x 10 ft (2.4 m) FCL10: 1.25” x 10 ft (2.4 m) suction1” x 10 ft (2.4 m) discharge
Operating Temperature
Fluid Temperature
30°F to 225°F (0°C to 105°C)
Ambient Temperature
-4°F to 104°F (-20C to 40C)
Materials of Construction
Housing
Carbon steel with industrial coating
Hoses
Reinforced synthetic
Wands
Stainless steel
Electric Motor
TEFC, 56-215 frame
0.5-3 hp, 1450-1750 RPM, see Appendix for amp ratings.
Electric Connection
Voltages 230 V ac and under, single phase: 35’ (11 m) retractable cord reel included. NEMA 5-15 plug installed on Power Option 12. Voltages over 230 V ac: 35’ (11 m) loose cord included.
Motor Starter
MSP (motor starter/protector) in an IP65, aluminum enclosure with short circuit and overload protection.
Pump
Cast iron, positive displacement gear pump with internal relief. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Pump Bypass
Full bypass at 150 psi (10 bar)2
Pneumatic Option Air Consumption
~40 cfm @ 80 psi3 35’ (11 m) retractable air hose included when pneumatic option selected. Replaces 35’ (11m) electric cord reel.
Media Description
M
Microglass, high performance glass media for all hydraulic & lubrication fluids. βx[C] = 1000 (βx = 200)
A
Microglass high performance media combined with water removal scrim. βx[C] = 1000 (βx = 200)
W
Stainless steel wire mesh media βx[C] = 2 (βx = 2)
VTM
β0.9[C] = 1000 particulate, insoluble oxidation by-product and water removal media
Viscosity
2-5000 cSt4
Fluid Compatibility
Petroleum and mineral based fluids, #2 diesel fuels (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options.
Hazardous Environment Options
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D. Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord or cord reel will be included.

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. 10 GPM pump is rated for intermittent duty only at pressures above 100 psi. Continual operation with dual clogged filters resulting in operating pressures over 100 psi will reduce pump life and/or cause premature pump failure.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 800 cSt for sizing requirements.

Filter Assemblies & Housings

Order and customize your order quickly and easily.
Filter Assemblies & Housings

CFUM9 Model shown (2x MF90 in series)

Filter Assemblies & Housings

Bigger isn’t always better. The Compact Filter Unit provides you with the best filtration at a size you can take anywhere. Tried and true, the CFU is the ultimate filtration system in power and mobility. And with easy to change cartridge style MF90s, you can rest easy knowing your filtration will always exceed your expectations.

FSL SPECIFICATIONS

Dimensional
Height
21” (54 cm)
Lenght
21” (54 cm)
Width
12” (31 cm)
Weight
47 lbs (21 kg)
Connections
Inlet
¾” male JIC with 37° flare
Outlet
½” male JIC with 37° flare
Hoses
¾” x 8 ft (2.4 m) suction female JIC or BSPP swivel ½” x 8 ft (2.4 m) discharge female JIC or BSPP swivel
Operating Temperature
Fluid Temperature
30°F to 225°F ½” x 8 ft (2.4 m) discharge female JIC or BSPP swivel
Ambient Temperature
4°F to 104°F ½” x 8 ft (2.4 m) discharge female JIC or BSPP swivel
ΔP Indicator Trigger
22 psi (1.5 bar). Consult factory for other options.
Filter Assembly Bypass
25 psid (1.7 bard). Consult factory for other options.
Materials of Construction
Frame
Powder coated aluminum
Filter Assembly
Aluminum head
Hoses
Reinforced synthetic
Wands
Stainless steel
Element Bypass Valve
Nylon
Electric Motor
TEFC, 56C frame 7/16 hp, 1450-1750 RPM
Electric Connection
15’ (4.6 m) cord included installed on machine.
Pump
Positive displacement gear pump with relief valve. Maximum pressure on pump inlet 15 psi (1 bar). Consult factory for higher pressures.
Pump Bypass
Full bypass at 150 psi (10 bar)2
Pneumatic Option Air Consumption
~15 cfm @ 60 psi3
Media Description
M
High performance glass media for all hydraulic & lubrication fluids. βx[C] ≥ 4000 (βx ≥ 200)
A
High performance media combined with water removal scrim. βx[C]  4000 (βx ≥ 200)
W
Stainless steel wire mesh media βx[C] ≥ 2 (βx ≥ 2)
Viscosity
Max viscosity rated for 200 cSt.4
Fluid Compatibility
Petroleum and mineral based fluids (standard). For specified synthetics contact factory for compatibility with fluorocarbon seal option. For phosphate ester (P9) or skydrol fluid (S9) compatibility select fluid compatibility from special options.
Hazardous Environment Options
Select pneumatic powered unit (Power Option 00) or explosion proof NEC Article 501, Class 1, Division 1, Group C+D.Call for IEC, Atex or other requirements. If Explosion Proof option (X--) selected, no electrical cord will be included.

1. Dimensions are approximations taken from base model and will vary according to options chosen.
2. Selecting pneumatic power option removes electric cord.
3. Air consumption values are estimated maximums and will vary with regulator setting.
4. When sized and installed appropriately. Contact factory for applications above 200 cSt for sizing requirement.

KEYWORDS
Filter Assemblies and Housings
Filter housings
Filtration needs
High and low flow volumes
Air inlet filter housings
Compressed gas
Cartridge
Strainer

Filter Assemblies & Housings

Protect your filter elements, prevent contaminants from reaching critical components, and improve efficiency with specially designed filter housings and assemblies.

Filter assemblies and housings play a crucial role in industrial processes to safeguard equipment and ensure high product quality. Selecting the optimal products ensures efficient filtration, reduced maintenance, and extended equipment life, ultimately contributing to enhanced process reliability and product quality.

Our team at Bennett Filtration Products can help you choose the right filter housings and assemblies for your company’s filtration needs. We have filter assemblies and housings available for high and low flow volumes, and for single and multiple filter configurations.

Our catalog of filter housings contains cartridge, strainer, compressed gas, and air inlet filter housings designed to accommodate a wide spectrum of operating pressures, from standard industrial settings to vacuum pressures of up to 10,000 psi.

We help you choose the right filtration equipment to meet your cleaning standards.

Contact us

keep browsing